Under Construction
Wind chill takes into account how the speed of the wind affects our perception of the air temperature. Our bodies warm the surrounding air molecules by transferring heat from the skin. If there’s no air movement, this insulating layer of warm air molecules stays next to the body and offers some protection from cooler air molecules. However, wind sweeps that comfy warm air surrounding the body away. The faster the wind blows, the faster heat is carried away and the colder the environment feels.
Heat Index uses temperature and relative humidity to determine how hot the air actually "feels." When humidity is low, the apparent temperature will be lower than the air temperature, since perspiration evaporates rapidly to cool the body. However, when humidity is high (i.e., the air is saturated with water vapor) the apparent temperature "feels" higher than the actual air temperature, because perspiration evaporates more slowly.
Dewpoint is the temperature to which air must be cooled for saturation (100% relative humidity) to occur, providing there is no change in water content. The dewpoint is an important measurement used to predict the formation of dew, frost, and fog. If dewpoint and temperature are close together in the late afternoon when the air begins to turn colder, fog is likely during the night. Dewpoint is also a good indicator of the air's actual water vapor content, unlike relative humidity, which is air temperature dependent. High dewpoint indicates high vapor content; low dewpoint indicates low vapor content. In addition a high dewpoint indicates a better chance of rain and severe thunderstorms. Dewpoint can be used to predict the minimum overnight temperature. Provided no new fronts are expected overnight and the afternoon Relative Humidity >=50%, the afternoon’s dewpoint gives an idea of what minimum temperature to expect overnight. Since condensation occurs when the air temperature reaches the dewpoint, and condensation releases heat into the air, reaching the dewpoint halts the cooling process.
Like Heat Index, the THSW Index uses humidity and temperature to calculate an apparent temperature. In addition, THSW incorporates the heating effects of solar radiation and the cooling effects of wind (like wind chill) on our perception of temperature.
The first term is humidity. This term is determined in the same manner as the Heat Index. This term serves as a base number to which increments of wind and sun are added to come up with the final THSW Index temperature.
The second term is wind. Depending upon your version of firmware or software, this term is determined in part by a lookup table (for temperatures above 50°F) and in part by the wind chill calculation, or uses an integrated table that is used both for calculation of this term and for wind chill. With this in mind, the following criterion apply with later versions referring to Vantage Pro2 console firmware revision May 2005 or later or WeatherLink version 5.6 or later:
The third term is sun. This term, Qg, is actually a combination of four terms (direct incoming solar, indirect incoming solar, terrestrial, and sky radiation). The term depends upon wind speed to determine how strong an effect it is. The value is limited to between -20 and +130 W/m2 in the Vantage Pro2 console firmware and WeatherLink software versions 5.6 or later.
The weight of the air that makes up our atmosphere exerts a pressure on the surface of the earth. This pressure is known as atmospheric pressure. Generally, the more air above an area, the higher the atmospheric pressure, this, in turn, means that atmospheric pressure changes with altitude. For example, atmospheric pressure is greater at sea-level than on a mountaintop. To compensate for this difference and facilitate comparison between locations with different altitudes, atmospheric pressure is generally adjusted to the equivalent sea-level pressure. This adjusted pressure is known as barometric pressure. In reality, the Vantage Pro and Vantage Pro2 measures atmospheric pressure. When entering the location’s altitude in Setup Mode, the Vantage Pro and Vantage Pro2 calculates the necessary correction factor to consistently translate atmospheric pressure into barometric pressure.
Barometric pressure also changes with local weather conditions, making barometric pressure an extremely important and useful weather forecasting tool. High pressure zones are generally associated with fair weather while low pressure zones are generally associated with poor weather. For forecasting purposes, however, the absolute barometric pressure value is generally less important than the change in barometric pressure. In general, rising pressure indicates improving weather conditions while falling pressure indicates deteriorating weather conditions.
Under normal conditions, rain rate data is sent with a nominal interval of 10 to 12 seconds. Every time a rain tip or click occurs, a new rain rate value is computed (from the timer values) and the rate timers are reset to zero.
Rain rate is calculated based on the time between successive tips of the rain collector. The rain rate value is the highest rate since the last transmitted rain rate data packet. (Under most conditions, however, a rain tip will not occur every 10 to 12 seconds.)
If there have been no rain tips since the last rain rate data transmission, then the rain rate based on the time since that last tip is indicated. This results in slowly decaying rate values as a rain storm ends, instead of showing a rain rate which abruptly drops to zero. This results in a more realistic representation of the actual rain event.
If this time exceeds roughly 15 minutes, than the rain rate value is reset to zero. This period of time was chosen because 15 minutes is defined by the U.S. National Weather Service as intervening time upon which one rain "event" is considered separate from another rain "event". This is also the shortest period of time that the Umbrella will be seen on the display console after the onset of rain.
Evapotranspiration (ET) is the amount of water that moves from the ground (and plants on the ground) to the atmosphere through both evaporation and transpiration. It is primarily important to people who are monitoring plant growth and associated water usage.
Measuring actual ET for a given location requires the measurement of weather variables at different heights at the same location and is beyond the capabilities of the current Davis weather stations. Instead, a single set of weather data measurements (described in detail below) are used to calculate a Reference ET (ETo). ETo is the amount of ET that is expected at a location with specified reference conditions under the actual weather conditions. The two most common reference conditions used for agricultural purposes are the grass reference – well watered grass that completely shades the ground, is uniformly clipped to a few inches in height – and the alfalfa reference – similar to the grass reference with alfalfa instead of grass, and a different height. The Davis ET calculations all calculate ETo for a grass reference.
To determine actual ET from a reference ETo, multiply the ETo by a crop coefficient (Kc). The crop coefficient accounts for the type of plant, the maturity of the plant, and may include local factors such as soil type. Davis Instruments does not supply crop coefficients. It is up to the individual user to determine what Kc is appropriate. See below for a list of some sources. It is very important, when selecting Kc to make sure that the coefficient is for use with a grass reference. Do not use coefficients that were derived from alfalfa referenced ETo.
Solar radiation is the primary source of energy that drives evapotranspiration, but what is important is the net radiation, incoming radiation minus outgoing radiation, at all wavelengths. The Davis solar radiation sensor measures incoming radiation in the visible portion of the spectrum. From this we must subtract out the component that is reflected off the plant leaves. This value is called the albedo.
In addition to the radiation in the visible spectrum, we must also take account of the longer wavelength thermal radiation. This is modeled as black-body radiation coming from three sources at the measured air temperature. The first source is the portion of the sky that does not contain clouds, the second source is the portion of the sky containing clouds, and the third source is the ground radiating into the sky. The first two sources are incoming radiation and the third is outgoing radiation. In order to determine the relative contributions of source one and two, we need to calculate the percentage of the sky that is covered by clouds.
The cloud cover fraction is estimated by comparing the actual mean solar radiation received against the amount we would have received if the sky was clear. In order to calculate the clear sky radiation, it is necessary to calculate the height of the sun above the horizon (solar altitude angle). The altitude of the sun depends, in turn, on the latitude, longitude, day of the year, and time of the day.
The net radiation equation cited in the reference section does not represent the exact method that Davis weather stations use to calculate net radiation.